Information Name: | LWH / KTC rod-type linear displacement sensor |
Published: | 2015-04-23 |
Validity: | 30 |
Specifications: | Standard |
Quantity: | 0.00 |
Price Description: | |
Detailed Product Description: | Summary: This series of displacement sensors for measurement and control system, the displacement and length direct and absolute measurement. The maximum operating range up to 900mm and high-resolution (0.01mm) provides precise linear displacement measurement. Consider ease of installation and removal on the structural design of the sensor. Inside and outside the sensor surface structure after special treatment, can work under high speed and low wear state. Flexible cushion bearing front of the sensor can overcome some minor lateral stress transmission rod, ensure the sensor is working properly. Sensor fixed conductive material and structural design and other technology to ensure that even in the worst conditions the sensor can reliably. Sensor has four mounting slots, try to face when conducting material so easy to install under installation, to avoid the presence of small debris inside the sensor particles thus affecting the life of the sensor. LWH rod series parameter table (Table 1) Model LWH 75 100 125 150 175 200 225 250 275 300 350 400 450 Effective stroke (AE) mm 75 100 125 150 175 200 225 250 275 300 350 400 450 electrical stroke mm 76 102 127 152 177 203 228 253 278,304,356,406,457 resistance KΩ ± 10% 3 5 10 Resistance Tolerance ±% 20 Linearity ±% 0.1 0.1 0.09 0.08 0.07 0.06 0.06 0.05 0.05 0.05 0.05 0.05 0.05 Repeatability mm 0.013 Resolution infinite resolution power Brush operating current 10MΩ insulation strength (50Hz, 2s, 1bar, 500VDC) <100μA mechanical stroke mm (size MT) 83 109 134 160 185 210 236 261 286 312 363 414 465 housing length mm (size A) 139 164 190 215 240 266 291 317 342,368,418,469,519 driving force in the horizontal direction <10N vertical 50X106 times the operating speed of 10m / s max acceleration run 200 (20g) m / s 2max protection class IP54 (DIN400 50 / IEC 529) LWH rod series parameters (Table b) Type LWH 500 550 600 650 700 750 800 850 900 950 1000 1150 1250 Effective stroke (AE) mm 500 550 600 650 700 750 800 850 900 950 1000 1150 1250 electrical stroke mm 508 559 610 661 712 762 813 863 914 964 1015 11,581,259 resistance KΩ ± 10% 10 20 Resistance Tolerance ±% 20 Linearity ±% 0.05 0.05 0.05 0.05 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04 Repeatability mm 0.013 Resolution infinite resolution brushes operating current 10MΩ insulation strength (50Hz , 2s, 1bar, 500VDC) <100μA mechanical stroke mm (size MT) 515 566 617 667 718 769 820 871 922 972 1022 housing length mm (size A) 570 621 671 721 772 822 873 923 974 1024 1075 driving force in the horizontal direction < 10N vertical 50X106 times the operating speed of 10m / s max acceleration run 200 (20g) m / s 2max protection class IP54 (DIN400 50 / IEC 529) Features: Long life - running times of up to 50 × 106 times, excellent linear resolution 0.01mm high operating speeds higher than standard plugs and sockets DIN430650 protection IP67 Description: Anodized aluminum casing assembly withhold gearing stainless steel mounting bracket, swivel bearings slewing bearings conductive plastic resistance element more shock precious metal brush brush assembly with elastic damping DIN43650 standard 4-pole electrical connector socket silvered shipments contain: a free outlet GDM3009 1 sealed pad GDM3-16 2 fixed brackets and four screws Recommended accessories: hinged head (see annex) Z60 / Z301 Process Control MAP is used to display the output directly to the display signal conditioner MUW / MUK, for normalized output signal V / A converter module, optional two-wire or three-wire current Important: linearity specifications listed in life and temperature coefficient and other parameters, the sensor work with op amp as a sensor output signal voltage divider circuit interface, and when the load current brush le≤1μA shipped by including: Recommended accessories: Note: The installation instructions free outlet GDM2009 EDM33 -98 Numerical linearity fulcrum (see annex) Z60 in the data listed in the table, service life, micro-linearity, anti-interference and prevent partial pressure in the form of temperature coefficient, the sensor working as a voltage in the operational amplifier output voltage output to the brush, and without load (le <1μA) obtained on condition brush. Recommend using the slider below the "inverted" Install only in this way is installed, in order to ensure the use of sensors in a variety of environments to provide effective protection for the detection element. A ring GDM3-16EEM 33-99, MAP process control monitor with display head two mounting brackets and four screws signal conditioner MUW / MUK, used to calibrate the output signal. Subject to change without notice. |
Admin>>>
You are the 6363 visitor
Copyright © GuangDong ICP No. 10089450, Mayen Sensing Technology Co., Ltd. of Shenzhen City All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6363 visitor
Copyright © GuangDong ICP No. 10089450, Mayen Sensing Technology Co., Ltd. of Shenzhen City All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility